RoentDek PRODUCT LIST 2011
DETECTOR
INSTALLATION, VACUUM FEEDTHROUGHS, SIGNAL DECOUPLING AND AMPLIFICATION
|
| |
|
|
|
| |
Product number
|
Product
Description |
|
| |
350 |
FT12-TP(or FT12-TPhex) 12-pin-ceramics-UHV-feedthrough and HF signal de-coupler on CF35 (ICF70) norm with UHV-cables for delay line detector (DLD), fitted to customer needs (max. 0.5 m), rated up to 4 kV DC.IIncludes BA3
battery box.
MANUAL |

 |
| |
|
FT12(-TP)/XXX: FT12(-TP) with mounting kit for DLD 40/80/120 and CFxxx-CF35 adapter flange (ICF153/203/253-ICF70) for direct mounting. The adjacent port must have at least xxx mm open diameter.
MANUAL
|
| |
|
|
| |
351 |
FT12-TP/100 for DLD40
DRAWING |
| |
|
|
| |
352 |
FT12-TP/150 for DLD80
DRAWING |
| |
|
|
| |
354 |
FT12-TP/200 >for DLD120
DRAWING |
| |
|
|
| |
355 |
FT16-TP: 12+4-pin-ceramics-UHV-feedthroughs and HF signal de-coupler on CF35 (ICF70) norm (2 flanges) with UHV-cables for Hexanode delay line detector fitted to customer needs (max. 0.5 m), rated up to 4 kV DC. Includes FT12-TPhex, BA3 battery box and 3 HFSD/HFST signal terminator/decoupler.
MANUAL |
| |
|
|
| |
356
|
FT16-TP/200: FT16-TP with
mounting kit for Hex75/HEX80 and CF200-CF352 adapter flange
(ICF253-ICF702) for direct mounting. The adjacent port must have
at least 200mm open diameter.
DRAWING
|
| 357 new |
FT16-TP/250: FT16-TP with
mounting kit for Hex120/HEX100... |
| |
|
|
|
| |
359 |
FT4-TP: 4-fold MHV ceramics UHV-feedthrough on CF35(ICF70) incl. in-vacuum cables and 3 HFSD/HFST signal terminator/decoupler. For DET40.
DRAWING |
|
| |
|
|
|
| |
360 |
LCHex40: position sensitive delay-line anode (Hexanode) for image charge pickup from RS-DET40 or similar detectors heads. |
|
| |
|
|
|
| |
094/093 |
Potential Mesh: (with 1 mm hexagons)
|
for DLD40 (transmission >85%)
for DLD80/HEX75/80 (transmission >80%) |
|
| |
|
|
|
| 096/095 new |
Wowen potential Mesh:
(with 140 micron open cell)
|
for DLD40 (transmission >75%)
for DLD80/HEX75/80 (transmission >75%) |
| |
|
| 097 new |
Calibration masks |
for DLD40/DLD80 or HEX75/80 |
| |
|
| |
|
| |
|
| |
|
| |
|
| 123 |
ECL2TTL: Active 8-fold ECL-TTL converter. Requires +/-5 or 6V DC for operation. |
| |
|
| |
|
| |
361 |
SHFD-SHFT: HF-signal de-coupler or terminator. Detector side MHV (or SHV), high voltage input SHV, HF-signal
output to lemo00 socket or terminated by 0-200Ohm. |
 |
| |
|
|
| |
|
|
| |
|
|
|
| |
363 |
Pinv&att: Signal inverter and/or attenuator for fast and short signals, bandwidth 1-500MHz, 50Ohm coax lemo00 in- and output. |
 |
| |
|
|
| |
364 |
SP1: in-line spark protector, lemo00 in-/output |
|
| |
|
|
|
| |
191
194
195
196
197
|
Cable sets ("lemo") for connections FT12(16)TP - ATR19 and ATR19 -
TDC8HP
Single cable (8 m, 4 m, 2 m = 10 ns, 1 m = 5 ns, 4 ns, 3 ns, 2 ns, 1 ns)
Set of 5 cables (4 m, different colors)
Set of 8 cables (4 m, different colors)
Set of 4 x 1 m,
of 4 x 2 m, of 2 x 4 m
Set for CFD1b/4b/8b : 1 ns, 2 ns, I-connector, 4x4 ns, 4 x 5 ns |
|
| |
|
|
|
| 199 |
Lemo starker kit: misc. connectors/adapter (10 total) plus 22 m lemo cables |
| |
|
|
|
| |
137 |
ATR19-x: 6/8-channel standard front-end electronics (amplifier and constant fraction discriminator) in 19” rack standard (1HU) with 100-125V / 200-250V AC adapter for RoentDek delay-line detectors in combination with FT4/12/16-TP-type connectors.
ATR19-6 for DLD40/80/120 (6 channels)
ATR19-8 for HEX80/75 (8 channels)
MANUAL |

 |
| |
138 |
ATR19-2: two channel version (3HU) without internal mains adapter (requires clean ±6V DC source, e.g. SPS1)
DESCRIPTION SHEET
|
|
| |
|
|
 |
|
380 |
SPS1: low noise external mains adapter for ATR19(-2), (N)DLATR8/6, ECL2TTL and similar
units. Input 100-125V/200-250V AC, output +/-5.2V to +/-6V, 1A/2A, incl. connection cable to 9-pin Sub-D plug. |
| |
|
|
|
| |
130 |
FAMP8: 8-channel fast timing amplifier unit for amplification of fast detector signals (as from MCP, delay-line anode, channeltron, photo-multiplier, etc.), gain about 55 (adjustable within +/- 10%, channels 7 and 8 from 0-110%), positive or negative input, bandwidth 2-300MHz, both inverting and non-inverting output. 19” rack case with external mains power adapter (100-250VAC). Signal input/output via lemo connector (50Ohm impedance). For use with standard constant fraction discriminator (CFD) or fast ADC systems. For advanced read-out of RoentDek detectors (in combination with FT4/12/16-TP and additional fast CFDs, e.g. CFD8c or fADC).
DESCRIPTION SHEET |

 |
| |
|
|
|
| |
131 |
FAMP1+:single fast timing amplifier unit for amplification of fast detector signals (performance/purpose) like FAMP8 but as single box unit incl. mains adapter (100-250V AC).
MANUAL |
 |
| |
|
133 |
PreFAMP6: 6-channel fast timing preamplifier unit with 5x gain, selectable bandwidth and input impedance. External bias input (+/- 6V) required, e.g. from SPS1b.
DESCRIPTION SHEET |
|
|
|
| 134 |
FAMP3(b): 3-channel fast timing amplifier unit with adjustable gain (up to 300x), bandwidth and input
impedance, inverting and non-inverting outputs, as 3HU 19” case.
DESCRIPTION SHEET |
| |
|
| |
135 new |
(D)FAMP6(b): 3-channel fast (Differential) timing amplifier unit with adjustable gain, bandwidth and input impedance, inverting and non-inverting outputs, as single width NIM unit. Optional mains adapter available on request |
|
| |
|
|
|
| |
140 |
MIXA8: 8-channel analog signal mixing amplifier. Multi-purpose module for signal shaping, mixing and multiplying. 19” rack case (1HU) with internal mains power adapter (100-250V AC). Signal input/output via Lemo connector (50Ohm
impedance).
DESCRIPTION SHEET |

 |
| |
|
|
|
| |
150 |
CFD8c: 8-channel constant fraction discriminator for advanced detector operation in combination with FAMP8. 19" rack case (1HU) with internal mains power adapter (100-250V AC). Multi-hit dead-time 10ns for fast signals (e.g. MCP signal). 300 MHz bandwidth, adjustable threshold, walk, delay, fraction ratio. Analog and digital monitor outputs. NIM and ECL timing outputs with adjustable signal width.
DESCRIPTION SHEET |
 |
|
|
|
|
151 |
CFD4c: constant fraction discriminator like 150, but with 4 channels and a single width NIM unit. Requires a NIM-bin for operation (with ± 6V), not included.*
DESCRIPTION SHEET |
| |
|
|
| |
152 |
CFD1c: 1-channel version of CFD8b with external mains power supply. |
| |
|
|
| 153 new |
CFDX: single-channel CFD incl. pulse-height to NIM pulse-width converter for measuring signal pulse height and signal timing. Single width NIM unit. Requires a NIM-bin for operation (with ± 6V), not included.*
|
| |
|
| 154 new |
LET1: leading edge discriminator for counting, coincidence detection or lowresolution timing tasks. Single box unit incl. mains adapter (100-250V AC) |
| |
|
| |
160 |
LogX4: 4-channel Logic Module for NIM signals. Eight logic function (and invert) for up to two NIM input signals (min. input length 5ns), e.g. AND, OR, NOT, EQ. 3 NIM outputs per channel plus one inverted with variable output length from 10ns to 10µs. Two channels can be combined to a Gate&Delay circuit. Single width NIM unit.
Requires a NIM-bin for operation (with ±6V), not included.*
DESCRIPTION SHEET |
|
|
|
| 162 new |
LogX4: Please inquire for single channel stand alone module |
| |
|
| |
161 |
FanO4: 4-channel logic NIM signal multiplexer with five outputs per channel. Optimized for timing
applications. Single width NIM unit. Requires a NIM-bin for operation (with ± 6V), not included.*
DESCRIPTION SHEET |
| |
|
|
|
| |
170 |
APG1: Test pulser for testing and calibration of electronic modules. Provides Nim pulser and attenuated pulses (40 dB) with adjustable repetition rate and width. Single box powered via USB-port or external +6V source (e.g. battery).
DESCRIPTION SHEET |
|
| |
|
|
|
| |
|
Please contact us for special delay-line anode sizes, delay- line anodes with phosphor screen and one-dimensional delay-line anodes at:
|
|
| |
|
*Please inquire for optional mains adapter (100-250V AC) for LogX4 and FanO4 and